{"help": "https://data.gov.au/data/en/api/3/action/help_show?name=datastore_search", "success": true, "result": {"include_total": true, "limit": 100, "records_format": "objects", "resource_id": "645a3c29-13ec-4622-9375-287ddf361c97", "total_estimation_threshold": null, "records": [{"_id":1,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2905","Floor ID":"BASEMENT 1","Room No/Name":"BUILDING STATUTORY COMPLIANCE PET GIS - HALLWAY LINKING OFFICES","Location Description":"THROUGHOUT CEILING","Survey ID":"2905","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"CEILING LINING","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":null,"Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"2.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB2165","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":2,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2906","Floor ID":"BASEMENT 1","Room No/Name":"SECONDARY STORAGE","Location Description":"WESTERN WALL","Survey ID":"2906","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"WALL LINING","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":"WALL LINING ASSOCIATED WITH ROLLER DOOR.","Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"5.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB2166","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":3,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2907","Floor ID":"BASEMENT 1","Room No/Name":"STORE G4","Location Description":"AIR CONDITIONER UNIT","Survey ID":"2907","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"INSULATION TO A/C UNIT","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":null,"Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"VERMICULITE","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"2.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB2159","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":4,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2910","Floor ID":"BASEMENT 1","Room No/Name":"CARPARK","Location Description":"SOUTHERN WALL","Survey ID":"2910","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"WALL LINING","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":"WALL ASSOCIATED WITH PRINT ROOM ENTRY.","Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"10.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB2167","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":5,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"4529","Floor ID":"BASEMENT 1","Room No/Name":"THROUGHOUT FLOOR","Location Description":"ALARMED FIRE DOORS","Survey ID":"4620","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":null,"Asset":"20008251","Application":"FIRE DOOR","Area":"10,000.000 m2","Asessment Date":"25/02/2015","City":"NERANG","Comments":"INTERNAL FIRE DOORS STAMPED FOR INSTALLATION POST 1987. ALARMED DOORS-NO INSTALLATION DATE.","Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"UNKNOWN","Friability":"LOW","Re-Insp Due":null,"Material":"INSULATION MATERIAL","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":null,"Prev Surv Ind":"X","Quantity":"8.000","Recommend Control":"LEAVE INSITU & MANAGE","Risk Rating":"LOW","Sample No":"SUSPECT","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"ASBESTOS PRESENT","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":6,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2889","Floor ID":"GROUND FLOOR","Room No/Name":"EXTERIOR","Location Description":"WESTERN AWNING","Survey ID":"2889","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"CEILING LINING","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":null,"Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"12.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB2162","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":7,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2896","Floor ID":"GROUND FLOOR","Room No/Name":"OPERATIONAL AND EXPERIMENTAL ASSESSMENT","Location Description":"UPPER NORTHERN AND EASTERN WALLS","Survey ID":"2896","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"INFILL PANEL","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":"INFILL PANELS ARE IN THE CEILING SPACE.","Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"5.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"SIM PB2170","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":8,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2897","Floor ID":"GROUND FLOOR","Room No/Name":"OPERATIONAL AND ENVIRONMENTAL ASSESSMENT","Location Description":"NORTHERN FIRE STAIR","Survey ID":"2897","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":null,"Asset":"20008251","Application":"FIRE DOOR","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":null,"Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":null,"Friability":null,"Re-Insp Due":null,"Material":"INSULATION MATERIAL","Area Not Accessed":"FIRE DOOR NOT ACCESSED DUE TO DESTRUCTIVE NATURE OF THE PROCEDURE.","No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"2.000","Recommend Control":"LEAVE INSITU & MANAGE","Risk Rating":"LOW","Sample No":null,"Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"WRONG ENTRY","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":9,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2898","Floor ID":"GROUND FLOOR","Room No/Name":"OPERATIONAL AND ENVIRONMENTAL ASSESSMENT","Location Description":"NORTHERN FIRE DOOR","Survey ID":"2898","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":null,"Asset":"20008251","Application":"FIRE DOOR","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":null,"Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"UNKNOWN","Friability":null,"Re-Insp Due":null,"Material":"INSULATION MATERIAL","Area Not Accessed":"FIRE DOOR NOT ACCESSED DUE TO DESTRUCTIVE NATURE OF THE PROCEDURE.","No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"2.000","Recommend Control":"LEAVE INSITU & MANAGE","Risk Rating":"LOW","Sample No":"SUSPECT","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"WRONG ENTRY","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":10,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2899","Floor ID":"GROUND FLOOR","Room No/Name":"HR AND ORGANISATIONAL DEVELOPMENT","Location Description":"AIR CONDITIONER UNITS HEATER BANKS","Survey ID":"2899","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"INSULATION TO A/C HEATER INSIDE SUPPLY AIR DUCT","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":null,"Condition":"MODERATE DAMAGE OR DETERIORATION","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"INSULATION MATERIAL","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"1.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB2168","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":11,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2900","Floor ID":"GROUND FLOOR","Room No/Name":"EXTERIOR","Location Description":"WESTERN CANTEEN AWNING","Survey ID":"2900","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"CEILING LINING","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":"AWNING ASSOCIATED WITH WESTERN CANTEEN CAR PARKING AREA.","Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"30.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"SIM PB 2162","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":12,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2901","Floor ID":"GROUND FLOOR","Room No/Name":"THROUGHOUT FLOOR","Location Description":"FIRE DOORS","Survey ID":"2901","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":null,"Asset":"20008251","Application":"FIRE DOOR","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":null,"Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"UNKNOWN","Friability":null,"Re-Insp Due":null,"Material":"INSULATION MATERIAL","Area Not Accessed":"FIRE DOOR NOT ACCESSED DUE TO DESTRUCTIVE NATURE OF THE PROCEDURE.","No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"60.000","Recommend Control":"LEAVE INSITU & MANAGE","Risk Rating":"LOW","Sample No":"SUSPECT","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"WRONG ENTRY","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":13,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2902","Floor ID":"GROUND FLOOR","Room No/Name":"EXTERIOR","Location Description":"TELSTRA SERVICE PITS SURROUNDING BUILDING","Survey ID":"2902","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"SERVICE PIT","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":null,"Condition":"MODERATE DAMAGE OR DETERIORATION","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT CASTING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"8.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB2163","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":14,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2904","Floor ID":"GROUND FLOOR","Room No/Name":"DETACHED GENERATOR ROOM","Location Description":"EXTERIOR - SOUTH SIDE ABOVE DOOR AND LOURVES TO THE ROOM","Survey ID":"2904","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"INFILL PANEL","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":"3X PANELS","Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"3.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB29949","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"WRONG ENTRY","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":15,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2908","Floor ID":"GROUND FLOOR","Room No/Name":"ATRIUM/MAIN OPEN AREA","Location Description":"UNDERSIDE OF STAIRCASE HEADING TO LEVEL 1","Survey ID":"2908","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"INFILL PANEL","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":"UNDERSIDE OF STAIRCASE LINING.","Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"10.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB2169","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":16,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2909","Floor ID":"GROUND FLOOR","Room No/Name":"BATS BUILDING AND PLANNING - FEMALE TOILET","Location Description":"THROUGHOUT WALLS","Survey ID":"2909","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"WALL LINING","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":"WALL LINING PRESENT BENEATH CERAMIC WALL TILES.","Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"10.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"SIM PB2164","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":17,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2911","Floor ID":"GROUND FLOOR","Room No/Name":"BATS BUILDING AND PLANNING - MALE TOILET","Location Description":"THROUGHOUT WALLS","Survey ID":"2911","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"WALL LINING","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":"WALL LINING PRESENT BENEATH CERAMIC WALL TILES.","Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"15.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB2164","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":18,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2912","Floor ID":"GROUND FLOOR","Room No/Name":"BUILDING CERTIFICATION OFFICE","Location Description":"UPPER NORTHERN AND EASTERN WALLS","Survey ID":"2912","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"INFILL PANEL","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":"INFILL PANELS ARE IN THE CEILING SPACE.","Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"2.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB2170","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":19,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2913","Floor ID":"GROUND FLOOR","Room No/Name":"BUILDING CERTIFICATION OFFICE AND KITCHENETTE","Location Description":"THROUGHOUT FLOOR","Survey ID":"2913","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"FLOOR COVERING","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":null,"Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"VINYL SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"2.500","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"SIM PB2171","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":20,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2914","Floor ID":"GROUND FLOOR","Room No/Name":"CUSTOMER SERVICE KITCHENETTE","Location Description":"THROUGHOUT FLOOR","Survey ID":"2914","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"FLOOR COVERING","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":null,"Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"VINYL SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"2.500","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB2171","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":21,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2915","Floor ID":"GROUND FLOOR","Room No/Name":"DETACHED GENERATOR ROOM","Location Description":"EXHAUST PIPE MANIFOLD","Survey ID":"2915","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"LAGGING","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":"TWO LAGGINGS TO EXHAUST PIPE MANIFOLD.","Condition":"MODERATE DAMAGE OR DETERIORATION","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"TEXTILE","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"1.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB2160","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"WRONG ENTRY","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":22,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2916","Floor ID":"GROUND FLOOR","Room No/Name":"DETACHED GENERATOR ROOM","Location Description":"GASKETS TO DIESEL MOTOR","Survey ID":"2916","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"GASKET","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":"GA ON SIDE OF BASE OF BODY.","Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"CHRYSOTILE","Friability":null,"Re-Insp Due":null,"Material":"INSULATION MATERIAL","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"0.500","Recommend Control":"LEAVE INSITU & MANAGE","Risk Rating":"LOW","Sample No":"PB2161","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"WRONG ENTRY","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":23,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"4530","Floor ID":"GROUND FLOOR","Room No/Name":"FIRE DOORS","Location Description":"EAST AND WEST FIRE DOORS","Survey ID":"4621","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":null,"Asset":"20008251","Application":"FIRE DOOR","Area":"10,000.000 m2","Asessment Date":"25/02/2015","City":"NERANG","Comments":"POTENTIAL ASBESTOS CONTAINING FIRE DOORS.","Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"UNKNOWN","Friability":null,"Re-Insp Due":null,"Material":"INSULATION MATERIAL","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":null,"Prev Surv Ind":"X","Quantity":"4.000","Recommend Control":"LEAVE INSITU & MANAGE","Risk Rating":"LOW","Sample No":"SUSPECT","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"ASBESTOS PRESENT","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":24,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2894","Floor ID":"LEVEL 1","Room No/Name":"WEST SIDE OUTSIDE MEETING ROOM 2 ADJACENT NORTH WEST COURTYARD","Location Description":"A/C DUCT HEADERBOARD","Survey ID":"2894","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"INSULATION TO A/C HEATER INSIDE SUPPLY AIR DUCT","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":null,"Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"MILLBOARD","Area Not Accessed":null,"No Floors":"3","No Seal":"X","Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"2.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"HB-AC9","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":25,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2895","Floor ID":"LEVEL 1","Room No/Name":"DETACHED GENERATOR ROOM","Location Description":"EXTERIOR - NORTH LOWER WALL ABOVE FLOOR PLATFORM","Survey ID":"2895","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"INFILL PANEL","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":null,"Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"1.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB29950","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"WRONG ENTRY","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":26,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2903","Floor ID":"LEVEL 1","Room No/Name":"COUNCILLOR S ROBBINS OFFICE","Location Description":"PARTITION WALL BETWEEN OFFICES","Survey ID":"2903","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"WALL LINING","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":null,"Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"10.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB2158","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":27,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2890","Floor ID":"LEVEL 3","Room No/Name":"LIFT MOTOR ROOM","Location Description":"LIFT MOTOR","Survey ID":"4611","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":"8/04/2010","Analysis Type":"PLM + DS","Asset":"20008251","Application":"BRAKE PADS","Area":"10,000.000 m2","Asessment Date":"25/02/2015","City":"NERANG","Comments":"OWEN SAINTY OF PARSONS BRINCKERHOFF HAS DEEMED THIS PREVIOUS ITEM AS NOW NON ASBESTOS. PERCIEVED THE LIFT BRAKE PADS HAVE BEEN REPLACED AS MAINT BY LIFT TECHNICIAN","Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"CHRYSOTILE","Friability":null,"Re-Insp Due":"3 YEARS","Material":"INSULATION MATERIAL","Area Not Accessed":"NO ACCESS GAINED DURING 2015 RE-INSPECTION.","No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"0.500","Recommend Control":"LEAVE INSITU & MANAGE","Risk Rating":"LOW","Sample No":"PB29951","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"ASBESTOS REMOVED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":28,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2891","Floor ID":"LEVEL 3","Room No/Name":"COOLING TOWER ROOM","Location Description":"NORTH AND EAST WALLS","Survey ID":"2891","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"WALL LINING","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":null,"Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"40.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"SIM PB2157","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"WRONG ENTRY","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":29,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2892","Floor ID":"LEVEL 3","Room No/Name":"AIR CONDITIONER PLANT ROOM","Location Description":"SOUTHERN WALL","Survey ID":"2892","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"WALL LINING","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":null,"Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"40.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB2157","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"WRONG ENTRY","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":30,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"2893","Floor ID":"LEVEL 3","Room No/Name":"AIR CONDITIONER PLANT ROOM","Location Description":"HEATER BANK","Survey ID":"2893","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":null,"Analysis Type":"PLM + DS","Asset":"20008251","Application":"INSULATION TO A/C HEATER INSIDE SUPPLY AIR DUCT","Area":"10,000.000 m2","Asessment Date":"8/04/2010","City":"NERANG","Comments":null,"Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"INSULATION MATERIAL","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":"N/A","Prev Surv Ind":"X","Quantity":"2.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB2156","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":31,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"4527","Floor ID":"LEVEL 3","Room No/Name":"COOLING TOWER ROOM","Location Description":"EAST AND SOUTH WALLS","Survey ID":"4618","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":"8/04/2010","Analysis Type":"PLM + DS","Asset":"20008251","Application":"WALL LINING","Area":"10,000.000 m2","Asessment Date":"25/02/2015","City":"NERANG","Comments":null,"Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":null,"Prev Surv Ind":"X","Quantity":"40.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"SIM TO PB-2157","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"},{"_id":32,"FL/EQ No":"F-ADNERA-ADNGMN","FL/EQ Desc":"NERANG ADMIN","Survey Status Indicator":null,"Occurence ID":"4528","Floor ID":"LEVEL 3","Room No/Name":"AIR CONDITIONER PLANT ROOM","Location Description":"NORTH AND WEST WALLS","Survey ID":"4619","FL/EQ Ind":"Functional Location","Accessibility":null,"Activity and Movement":null,"Header Changed On":null,"Header Changed By":null,"Airplenum":null,"Sample Analysis Date":"8/04/2010","Analysis Type":"PLM + DS","Asset":"20008251","Application":"WALL LINING","Area":"10,000.000 m2","Asessment Date":"25/02/2015","City":"NERANG","Comments":null,"Condition":"NONE TO MINOR DAMAGE","Description":null,"Directorate":"Property Services","Header Created on":"23/05/2014","Fibre Type":"NO ASBESTOS DETECTED","Friability":null,"Re-Insp Due":null,"Material":"FIBRE CEMENT SHEETING","Area Not Accessed":null,"No Floors":"3","No Seal":null,"Asset Owner":"GCCC","PB Code":null,"Prev Surv Ind":"X","Quantity":"40.000","Recommend Control":"N/A","Risk Rating":"N/A","Sample No":"PB-2157","Sign Req":null,"Street":"SOUTHPORT NERANG ROAD","Survey Status":"NO ASBESTOS IDENTIFIED","Base Unit of Measure":"***","Usage":"ADMIN OR DEPOT BUILDING"}], "fields": [{"id": "_id", "type": "int"}, {"id": "FL/EQ No", "type": "text"}, {"id": "FL/EQ Desc", "type": "text"}, {"id": "Survey Status Indicator", "type": "text"}, {"id": "Occurence ID", "type": "text"}, {"id": "Floor ID", "type": "text"}, {"id": "Room No/Name", "type": "text"}, {"id": "Location Description", "type": "text"}, {"id": "Survey ID", "type": "text"}, {"id": "FL/EQ Ind", "type": "text"}, {"id": "Accessibility", "type": "text"}, {"id": "Activity and Movement", "type": "text"}, {"id": "Header Changed On", "type": "text"}, {"id": "Header Changed By", "type": "text"}, {"id": "Airplenum", "type": "text"}, {"id": "Sample Analysis Date", "type": "text"}, {"id": "Analysis Type", "type": "text"}, {"id": "Asset", "type": "text"}, {"id": "Application", "type": "text"}, {"id": "Area", "type": "text"}, {"id": "Asessment Date", "type": "text"}, {"id": "City", "type": "text"}, {"id": "Comments", "type": "text"}, {"id": "Condition", "type": "text"}, {"id": "Description", "type": "text"}, {"id": "Directorate", "type": "text"}, {"id": "Header Created on", "type": "text"}, {"id": "Fibre Type", "type": "text"}, {"id": "Friability", "type": "text"}, {"id": "Re-Insp Due", "type": "text"}, {"id": "Material", "type": "text"}, {"id": "Area Not Accessed", "type": "text"}, {"id": "No Floors", "type": "text"}, {"id": "No Seal", "type": "text"}, {"id": "Asset Owner", "type": "text"}, {"id": "PB Code", "type": "text"}, {"id": "Prev Surv Ind", "type": "text"}, {"id": "Quantity", "type": "text"}, {"id": "Recommend Control", "type": "text"}, {"id": "Risk Rating", "type": "text"}, {"id": "Sample No", "type": "text"}, {"id": "Sign Req", "type": "text"}, {"id": "Street", "type": "text"}, {"id": "Survey Status", "type": "text"}, {"id": "Base Unit of Measure", "type": "text"}, {"id": "Usage", "type": "text"}], "_links": {"start": "/api/action/datastore_search?resource_id=645a3c29-13ec-4622-9375-287ddf361c97", "next": "/api/action/datastore_search?resource_id=645a3c29-13ec-4622-9375-287ddf361c97&offset=100"}, "total": 32, "total_was_estimated": false}}