Queensland 2020 hourly PM10 data

Air Quality Monitoring - 2020 (grouped by pollutant)

Created 24/08/2025

Updated 24/08/2025

Period of reporting: 1 January to 31 December 2020

Monitoring sites: Brisbane CBD, Cannon Hill, Collingwood Park (until 28 February), Fisherman Island (until 31 May), Flinders View, Lytton, Mount Coot-tha, Mountain Creek, Rocklea, South Brisbane, Southport, Springwood, Woolloongabba, Wynnum North, Wynnum West (South East Queensland); Hopeland, Miles Airport, Tara Region (South West Queensland); Auckland Point, Boat Creek, Boyne Island, Clinton, Fisherman's Landing, South Gladstone, Targinie (Gladstone region); Blackwater, Emerald, Moranbah East, Moranbah West (Central Queensland); West Mackay (Mackay); Townsville Coast Guard, Townsville Environment Park, Townsville Lennon Drive, North Ward (Townsville); The Gap (Mount Isa)

Measurement units: micrograms per cubic metre (ug/m^3)

Measurement technique (Flinders View, Mountain Creek, Auckland Point, Bluff, The Gap): Tapered Element Oscillating Balance (TEOM) Model 1405 operated in accordance with AS/NZS 3580.9.16 (excluding FDMS requirements)

  • Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.
  • Reported concentrations are uncorrected instrument output values.
  • Negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.

Measurement technique (Brisbane CBD (until 8 January)): Tapered Element Oscillating Balance (TEOM) Model 1405-F fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.16

  • The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.
  • Reported concentrations are uncorrected instrument output values.
  • The reported PM10 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.
  • Negative hourly PM10 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.

Measurement technique (Lytton, Wynnum North, Wynnum West): Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-D operated in accordance with AS/NZS 3580.9.13 (excluding FDMS requirements)

  • Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.
  • Reported concentrations are uncorrected instrument output values.
  • Negative hourly PM10 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.

Measurement technique (Cannon Hill, Rocklea, Southport, Springwood, Fisherman's Landing, South Gladstone: Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.16

  • The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.
  • Reported concentrations are uncorrected instrument output values.
  • The reported PM10 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.
  • Negative hourly PM10 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.

Measurement technique (Brisbane CBD (from 8 January), Collingwood Park, Fisherman Island, Mount Coot-tha, South Brisbane, Woolloongabba, Boat Creek, Boyne Island, Clinton , South Gladstone (1 January to 3 February, 29 May to 17 June), Targinie, Blackwater, Emerald, Moranbah East, Moranbah West, West Mackay, Townsville Coast Guard, Townsville Environment Park, Townsville Lennon Drive, North Ward): Scattered light spectrometry (TAPI Model 640X) operated in accordance with USEPA equivalence method designation requirements

  • Reported concentrations are uncorrected instrument output values.

Measurement technique (Hopeland, Miles Airport, Tara Region): Optical light scattering method using Palas Fidas 200 instrument

Source

This data file or API can be downloaded from:

https://www.data.qld.gov.au/dataset/0eb54bde-fbc4-4b36-b3c4-d2824439d85b/resource/7fccaab3-657c-45c2-b8a3-9ea0277bd252/download/pm10-qld-2020.csv