<mdb:MD_Metadata xmlns:cit="http://standards.iso.org/iso/19115/-3/cit/2.0" xmlns:gco="http://standards.iso.org/iso/19115/-3/gco/1.0" xmlns:lan="http://standards.iso.org/iso/19115/-3/lan/1.0" xmlns:mcc="http://standards.iso.org/iso/19115/-3/mcc/1.0" xmlns:mdb="http://standards.iso.org/iso/19115/-3/mdb/2.0" xmlns:mrd="http://standards.iso.org/iso/19115/-3/mrd/1.0" xmlns:mri="http://standards.iso.org/iso/19115/-3/mri/1.0" xmlns:xlink="http://www.w3.org/1999/xlink">
    <mdb:metadataIdentifier xlink:type="simple">
        <mcc:MD_Identifier>
            <mcc:code>
                <gco:CharacterString>244cef2b-420a-4d5e-9f3e-f932da7afa0d</gco:CharacterString>
            </mcc:code>
            <mcc:codeSpace>
                <gco:CharacterString>urn:uuid</gco:CharacterString>
            </mcc:codeSpace>
        </mcc:MD_Identifier>
    </mdb:metadataIdentifier>
    <mdb:defaultLocale xlink:type="simple">
        <lan:PT_Locale>
            <lan:language>
                <lan:LanguageCode codeList="" codeListValue="en">en</lan:LanguageCode>
            </lan:language>
            <lan:characterEncoding>
                <lan:MD_CharacterSetCode codeList="" codeListValue="UTF-8">UTF-8</lan:MD_CharacterSetCode>
            </lan:characterEncoding>
        </lan:PT_Locale>
    </mdb:defaultLocale>
    <mdb:metadataScope xlink:type="simple">
        <mdb:MD_MetadataScope>
            <mdb:resourceScope>
                <mcc:MD_ScopeCode codeList="" codeListValue="nonGeographicDataset">nonGeographicDataset</mcc:MD_ScopeCode>
            </mdb:resourceScope>
            <mdb:name>
                <gco:CharacterString>nonGeographicDataset</gco:CharacterString>
            </mdb:name>
        </mdb:MD_MetadataScope>
    </mdb:metadataScope>
    <mdb:contact xlink:type="simple" />
    <mdb:dateInfo xlink:type="simple">
        <cit:CI_Date>
            <cit:date>
                <gco:DateTime>2025-11-11T08:05:12</gco:DateTime>
            </cit:date>
            <cit:dateType>
                <cit:CI_DateTypeCode codeList="" codeListValue="creation">creation</cit:CI_DateTypeCode>
            </cit:dateType>
        </cit:CI_Date>
    </mdb:dateInfo>
    <mdb:metadataStandard xlink:type="simple">
        <cit:CI_Citation>
            <cit:title>
                <gco:CharacterString>ISO 19115</gco:CharacterString>
            </cit:title>
            <cit:edition>
                <gco:CharacterString>2016</gco:CharacterString>
            </cit:edition>
        </cit:CI_Citation>
    </mdb:metadataStandard>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Air Quality Monitoring - 2015</gco:CharacterString>
                    </cit:title>
                    <cit:identifier xlink:type="simple">
                        <mcc:MD_Identifier>
                            <mcc:code>
                                <gco:CharacterString>244cef2b-420a-4d5e-9f3e-f932da7afa0d</gco:CharacterString>
                            </mcc:code>
                        </mcc:MD_Identifier>
                    </cit:identifier>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>Annual hourly air quality and meteorological data by monitoring site for the 2015 calendar year. For more information on air quality, including live air data, please visit environment.des.qld.gov.au/air.  
Data resolution: One-hour average values (one-hour sum for rainfall)
Data row timestamp: Start of averaging period
Missing data/not monitored: Blank cell
Calm conditions: No hourly average wind direction is reported when the hourly average wind speed is zero
Barometric pressure: Values are at monitoring station elevation, not corrected to mean sea level
Daily zero/span response check: Automated instrument zero/span response checks are conducted daily between midnight and 1am at Queensland Government sites (can differ at industry sites). Where this takes place an ambient hourly value cannot be reported.
Sampling height: Four metres above ground (unless otherwise indicated)  
PLEASE NOTE: The Auckland Point 2015 air quality monitoring site data was updated on 23/04/2018 due to the wind direction sensor being misaligned and the reported wind direction values have now been corrected.</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:descriptiveKeywords xlink:type="simple">
                <mri:MD_Keywords>
                    <mri:keyword>
                        <gco:CharacterString>The Science Sandpit</gco:CharacterString>
                    </mri:keyword>
                </mri:MD_Keywords>
            </mri:descriptiveKeywords>
            <mri:descriptiveKeywords xlink:type="simple">
                <mri:MD_Keywords>
                    <mri:keyword>
                        <gco:CharacterString>air quality</gco:CharacterString>
                    </mri:keyword>
                </mri:MD_Keywords>
            </mri:descriptiveKeywords>
            <mri:descriptiveKeywords xlink:type="simple">
                <mri:MD_Keywords>
                    <mri:keyword>
                        <gco:CharacterString>environment</gco:CharacterString>
                    </mri:keyword>
                </mri:MD_Keywords>
            </mri:descriptiveKeywords>
            <mri:descriptiveKeywords xlink:type="simple">
                <mri:MD_Keywords>
                    <mri:keyword>
                        <gco:CharacterString>science</gco:CharacterString>
                    </mri:keyword>
                </mri:MD_Keywords>
            </mri:descriptiveKeywords>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Abbot Point (Bowen) 2015 hourly meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -19.9496; Longitude: 148.0482  
**AS/NZS 3580.1.1:2007 site classification:** Background  
**AS/NZS 3580.14:2011 compliance (meteorology):** Complies, except for:  

*    Temperature and relative humidity sensors located 10 metres above ground level.  

**Wind sensor:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +8 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*    Height above ground level: 10 metres.

**Relative humidity:** Capacitive thin film polymer sensor  

*    Height above ground level: 10 metres.

**Rainfall:** Vaisala RAINCAP® precipitation sensor.  

*    Height above ground level: 10 metres.

**Barometric pressure:** Capacitive silicon sensor.  

*    Height above ground level: 10 metres. </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Aldoga (Gladstone) 2015 hourly meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015 (site offline 15 May to 20 December due to solar power system failure and site infrastructure upgrade)   
**Site location:** Latitude: -23.8409; Longitude: 151.0627  
**AS/NZS 3580.1.1 site classification:** Background  
**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Temperature and relative humidity sensors located 10 metres above ground level (21 December to 31 December).
*    Rainfall measured by acoustic sensor.  

**Wind:** Mechanical cup and vane (1 January to 15 May); Ultrasonic sensor (21 December to 31 December)  

*    Height above ground level: 10 metres.
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.  

**Temperature:** Platinum resistance sensor (1 January to 15 May); Capacitive ceramic sensor (21 December to 31 December)  

*    Height above ground level: 2 metres (1 January to 15 May)
*    Height above ground level: 10 metres (21 December to 31 December).  

**Relative humidity:** Capacitive thin film polymer sensor (21 December to 31 December)  

*    Height above ground level: 10 metres.

**Rainfall:** Vaisala RAINCAP® precipitation sensor (21 December to 31 December)  

*    Height above ground level: 10 metres.  

**Barometric pressure:** Capacitive silicon sensor (21 December to 31 December)  

*    Height above ground level: 10 metres.</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Ayr (Ayr) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -19.5839; Longitude: 147.4059  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Trees within 15 metres of the monitoring site.  

**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +8 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**PM10:** Tapered Element Oscillating Balance (TEOM) Model 1405 operated in accordance with AS/NZS 3580.9.13 (excluding FDMS requirements)  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Reported concentrations are uncorrected instrument output values.  
*    Negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1  
  
*    Detector spectral response centred at 530 nm.  
*    Instrument output offset and/or scaled based on calibration and daily zero/span response data. </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Auckland Point (Gladstone) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -23.8349; Longitude: 151.2539  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14:2011 compliance (meteorology):** Complies, except for:  

*    Located on southern side of slope below a ridge.  
*    Trees within 20 metres of the monitoring site.  
*    Temperature and relative humidity sensors located 10 metres above ground level (from 17 December).

**Wind:** Ultrasonic sensor  

*    Data invalid from 1 January to 16 December due to sensor fault
*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*    Height above ground level: 3 metres (1 January to 17 December)  
*    10 metres (17 December to 31 December). 

**Relative humidity:** Capacitive thin film polymer sensor (17 December to 31 December)  

*    Height above ground level: 10 metres.

**Rainfall:** Vaisala RAINCAP® precipitation sensor (17 December to 31 December)  

*    Height above ground level: 10 metres.  

**Barometric pressure:** Capacitive silicon sensor (17 December to 31 December)  

*    Height above ground level: 10 metres.

**PM10:** Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8—2001  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0).  
*    After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3. 

**UPDATED 23/04/2018:**  New dataset uploaded with corrections. 
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Boat Creek (Gladstone) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -23.8200; Longitude: 151.1539  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies fully  
**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**Relative humidity:** Capacitive thin film polymer sensor  
**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1  
  
*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1  
  
*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13  

*    The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*    Reported concentrations are uncorrected instrument output values.  
*    Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1  

*    Detector spectral response centred at 530 nm.  
*    Instrument output offset and/or scaled based on calibration and daily zero/span response data. </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Boyne Island (Gladstone) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -23.9408; Longitude: 151.3507  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14:2011 compliance (meteorology):** Complies, except for:  

*    Located on eastern side of slope below a ridge running north-south.  
*    Trees within 20 metres of the monitoring site.  

**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**Relative humidity:** Capacitive thin film polymer sensor  
**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Carbon monoxide:** Infrared absorption analyser operated in accordance with AS 3580.7.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13  

*    The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*    Reported concentrations are uncorrected instrument output values.  
*    Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1  

*    Detector spectral response centred at 530 nm.  
*    Instrument output offset and/or scaled based on calibration and daily zero/span response data. </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Brisbane CBD (South East Queensland) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -27.4774; Longitude: 153.0281  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for:  

*    Equipment located in room on sixth floor of building.  
*    Nephelometer inlet located on eastern side of building, 1 metre out from building.  
*    PM10 inlet located on building roof above equipment room, 1 metre above roof surface.  
*    Building lift shaft higher than PM10 inlet located 8 metres south of inlet.  

**AS/NZS 3580.14:2011 compliance (meteorology):** Complies, with exceptions:  

*    Building lift shaft higher than wind sensor and within 10 metres of sensor.  
*    Buildings higher than wind sensor located within 40 metres of sensor.  
*    Temperature sensor located in non-aspirated radiation shield 1 metre above the roof surface.  

**Wind:** Ultrasonic sensor  

*    Height above roof level: 4 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**PM10:** Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0).  
*    After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1  

*    Detector spectral response centred at 530 nm.  
*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Cannon Hill (South East Queensland) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015   
**Site location:** Latitude: -27.4654; Longitude: 153.0872  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Temperature and relative humidity sensors located 10 metres above ground level.  
*    Rainfall measured by acoustic sensor  

**Wind sensor:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*    Height above ground level: 10 metres.  

**Relative humidity:** Capacitive thin film polymer sensor  

*    Height above ground level: 10 metres.  

**Rainfall:** Vaisala RAINCAP® precipitation sensor.  

*    Height above ground level: 10 metres.  

**Barometric pressure:** Capacitive silicon sensor.  

*    Height above ground level: 10 metres.  

**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13  
  
*    The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*    Reported concentrations are uncorrected instrument output values.  
*    The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.
*    Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.  

**TSP:**Tapered Element Oscillating Microbalance (TEOM) Model 1405 operated in accordance with AS/NZS 3580.9.13 (excluding FDMS requirements)  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Reported concentrations are uncorrected instrument output values.  
*    Negative hourly TSP concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3. 
  </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Clinton (Gladstone) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -23.8701; Longitude: 151.2216  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14:2011 compliance (meteorology):** Complies, except for:  

*    Temperature and relative humidity sensors located 10 metres above ground level.  
*    Rainfall mesured by acoustic sensor  

**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor.  

*    Height above ground level: 10 metres.  

**Relative humidity:** Capacitive thin film polymer sensor.  

*    Height above ground level: 10 metres.  

**Rainfall:** Vaisala RAINCAP® precipitation sensor.  

*    Height above ground level: 10 metres.  

**Barometric pressure:** Capacitive silicon sensor.  

*    Height above ground level: 10 metres.  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13  

*    The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*    Reported concentrations are uncorrected instrument output values.  
*    The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.
*    Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1  

*    Detector spectral response centred at 530 nm.  
*    Instrument output offset and/or scaled based on calibration and daily zero/span response data. </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Deception Bay (South East Queensland) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -27.1935; Longitude: 153.0347  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Trees within 20m to the south-west of the monitoring station  

**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data. </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Flinders View (Ipswich, South East Queensland) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -27.6528; Longitude: 152.7741  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for:  

*    Trees above the height of inlet within 10 metres of the monitoring site.  

**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Located on western side of slope below a ridge running northeast-southeast.  
*    Trees within 10 metres of the monitoring site (below height of wind sensor).  

**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**Relative humidity:** Capacitive thin film polymer sensor  
**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with S/NZS 3580.4.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**PM10:** Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0).  
*    After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1:  

*    Detector spectral response centred at 530 nm.  
*    Instrument output offset and/or scaled based on calibration and daily zero/span response data. </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Gatton (South East Queensland) 2015 hourly meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 23 September 2015 (site offline from 24 September to 31 December due to site infrastructure upgrade)  
**Site location:** Latitude: -27.5434; Longitude: 152.3343  
**AS/NZS 3580.1.1:2007 site classification:** Background  
**AS/NZS 3580.14:2011 compliance (meteorology):** Complies fully  
**Wind:** Mechanical cup and vane  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Platinum resistance sensor  

*    Height above ground level: 2 metres. </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Hopeland (South West Queensland) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Industry-operated monitoring site:** Data presented as received by Queensland Government   
**Period of operation:** 14 January 2015 to 31 December 2015    
**Site location:** &lt;5 km km of Hopeland town centre   
**AS/NZS 3580.1.1 site classification:** Background   
**AS/NZS 3580.1.1 compliance (pollutants):** Complies   
**Temperature:** Solid state thermistor sensor   

*    Height above ground level: 10 metres.

**Wind:** Ultrasonic sensor

*    Height above ground level: 10 metres. 

**Rain:** Tipping bucket rain gauge   
**Relative humidity:** Capacitive thin film polymer sensor    
**Solar radiation:** Pyranometer   
**Ozone:** Ultraviolet photometry analyser operated in accordance with AS 3580.6.1   
**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1   
**Carbon Monoxide:** Infrared absorption analyser operated in accordance with AS 3580.7.1   
**TSP/PM2.5/PM10:** Optical light scattering method using Palas FIDAS 200</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Jondaryan (Jondaryan) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -27.3713; Longitude: 151.5934  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Temperature and relative humidity sensors located 10 metres above ground level.  
*    Rainfall measured by acoustic sensor  

**Wind sensor:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*    Height above ground level: 10 metres.  

**Relative humidity:** Capacitive thin film polymer sensor  

*    Height above ground level: 10 metres.

**Rainfall:** Vaisala RAINCAP® precipitation sensor.  

*    Height above ground level: 10 metres.  

**Barometric pressure:** Capacitive silicon sensor.  

*    Height above ground level: 10 metres.  

**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13  
  
*    The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*    Reported concentrations are uncorrected instrument output values.  
*    The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.
*    Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.  

**TSP:** Tapered Element Oscillating Microbalance (TEOM) Model 1405 operated in accordance with AS/NZS 3580.9.13 excepting FDMS requirements    

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Reported concentrations are uncorrected instrument output values.  
*    Negative hourly TSP concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3. 
  </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Josephville (South East Queensland) 2015 hourly meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -27.9962; Longitude: 152.9257  
**AS/NZS 3580.1.1 site classification:** Background  
**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Temperature and relative humidity sensors located 10 metres above ground level.  
*    Rainfall measured by acoustic sensor.  

**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*    Height above ground level: 10 metres.  

**Relative humidity:** Capacitive thin film polymer sensor  

*    Height above ground level: 10 metres.  

**Rainfall:** Vaisala RAINCAP® precipitation sensor  

*    Height above ground level: 10 metres.  

**Barometric pressure:** Capacitive silicon sensor.  

*    Height above ground level: 10 metres. </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Luscombe (South East Queensland) 2014 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:**  2 September (site established) to 31 December 2015  
**Site location:** Latitude: -27.7747; Longitude: 153.2014  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Temperature and relative humidity sensors located 10 metres above ground level.  
*    Rainfall measured by acoustic sensor.  

**Wind sensor:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*    Height above ground level: 10 metres.  

**Relative humidity:** Capacitive thin film polymer sensor  

*    Height above ground level: 10 metres.  

**Rainfall:** Vaisala RAINCAP® precipitation sensor.  

*    Height above ground level: 10 metres.  

**Barometric pressure:** Capacitive silicon sensor.  

*    Height above ground level: 10 metres.  

**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13  

*    The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.   
*    Reported concentrations are uncorrected instrument output values.   
*    The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.  
*    Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.  

**TSP:** Tapered Element Oscillating Microbalance (TEOM) Model 1405 operated in accordance with AS/NZS 3580.9.13 (excluding FDMS requirements)  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Reported concentrations are uncorrected instrument output values.   
*    Negative hourly TSP concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Lytton (South East Queensland) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Industry-operated monitoring site:** Data presented as received by Queensland Government  
**Period of operation:** 1 March to 31 December 2015  
**Site location:** Latitude: -27.4065; Longitude: 153.1527  
**AS/NZS 3580.1.1 site classification:** Peak  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology)** : Complies, except for:  

*    Temperature and relative humidity sensors located 10 metres above ground level.  
*    Rainfall measured by acoustic sensor.  

**Wind sensor:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  

**Temperature:** Capacitive ceramic sensor  

*    Height above ground level: 10 metres.  

**Relative humidity:** Capacitive thin film polymer sensor  

*    Height above ground level: 10 metres.  

**Rainfall:** Vaisala RAINCAP® precipitation sensor.  

*    Height above ground level: 10 metres.  

**Barometric pressure:** Capacitive silicon sensor.  

*    Height above ground level: 10 metres.  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1  
**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13  

*    The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*    Reported concentrations are uncorrected instrument output values.  
*    Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported. 
  </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Memorial Park (Gladstone) 2015 hourly air quality data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -23.8426; Longitude: 151.2534  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for:  

*    DOAS light path between 4 metres and 25 metres above ground level.  

**Ozone, nitrogen dioxide, sulfur dioxide, benzene, toluene, xylenes (total) and formaldehyde:** Differential Optical Absorption Spectroscopy (DOAS) analyser  

*    Reported value is average concentration over 520 metre light path running southwest-northeast from (-23.8443, 151.2517) to (-23.8409,151.2550).  
*    Instrument output offset and/or scaled based on instrument calibration data. 
 </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Menzies (Mount Isa) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -20.7167; Longitude: 139.4920  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for:  

*    Trees above height of inlet within 10 metres of monitoring site.  

**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Trees within 10 metres of monitoring site.  

**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +6 degrees to the sensor output value.  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data. 
  </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Miles Aiport (South West Queensland) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Industry-operated monitoring site:** Data presented as received by Queensland Government   
**Period of operation:** 2 July 2015 to 31 December 2015   
**Site location:** &lt;5 km of Miles Airport   
**AS/NZS 3580.1.1 site classification:** Background   
**AS/NZS 3580.1.1 compliance (pollutants):** Complies   
**Temperature:** Solid state thermistor sensor   

*   Height above ground level: 10 metres.

**Wind:** Ultrasonic sensor

*    Height above ground level: 10 metres. 

**Rain:** Tipping bucket rain gauge   
**Relative humidity:** Capacitive thin film polymer sensor   
**Solar radiation:** Pyranometer    
**Ozone:** Ultraviolet photometry analyser operated in accordance with AS 3580.6.1   
**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1   
**Carbon Monoxide:** Infrared absorption analyser operated in accordance with AS 3580.7.1   
**TSP/PM2.5/PM10:** Optical light scattering method using Palas FIDAS 200.   </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Moranbah (Moranbah) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -21.9995; Longitude: 148.0713  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies fully  
**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +8 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*    Sensor mounted in non-aspirated radiation shield 4 metres above ground level – under still conditions reported temperature can be higher than actual.  

**PM10 (1 January to 14 May):** Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0).  
*    After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3. 

**PM10 (15 May to 31 December):** Tapered Element Oscillating Balance (TEOM) Model 1405 operated in accordance with AS/NZS 3580.9.13, excepting FDMS requirements  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.
*    Reported concentrations are uncorrected instrument output values.
*    Negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Mountain Creek (Sunshine Coast, South East Queensland) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -26.6917; Longitude: 153.1038  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies fully  
**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**PM10:** Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0).  
*    After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1  

*    Detector spectral response centred at 530 nm.  
*    Instrument output offset and/or scaled based on calibration and daily zero/span response data. </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Mutdapilly (South East Queensland) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -27.7528; Longitude: 152.6509  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies fully  
**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data. </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>North Maclean (South East Queensland) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -27.7708; Longitude: 153.0300  
**AS/NZS 3580.1.1 site classification:** Background  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Temperature and relative humidity sensors located 10 metres above ground level.  
*    Rainfall measured by acoustic sensor.  

**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor.  

*    Height above ground level: 10 metres.  

**Relative humidity:** Capacitive thin film polymer sensor.  

*    Height above ground level: 10 metres.  

**Rainfall:** Vaisala RAINCAP® precipitation sensor.  

*    Height above ground level: 10 metres.  

**Barometric pressure:** Capacitive silicon sensor.  

*    Height above ground level: 10 metres.  

**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data. </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Pimlico (Townsville) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -19.2871; Longitude: 146.7813  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Isolated trees within 20 metres of the monitoring site.  
*    Three storey building located within 30 metres south of the monitoring site.  

**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +8 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*    Sensor mounted in non-aspirated radiation shield 4 metres above ground level – under still conditions reported temperature can be higher than actual.  

**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**PM10 (1 January to 19 May):** Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0).  
*    After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3. 

**PM10 (19 May to 31 December):** Tapered Element Oscillating Balance (TEOM) Model 1405 operated in accordance with AS/NZS 3580.9.13, excepting FDMS requirements  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.
*    Reported concentrations are uncorrected instrument output values.
*    Negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.  </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Pinkenba (South East Queensland) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Industry-operated monitoring site:** Data presented as received by Queensland Government  
**Period of operation:** 1 January to 4 November 2015 (site closed)  
**Site location:** Latitude: -27.4187; Longitude: 153.1330  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies fully  
**Wind sensor:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  

**Temperature:** Capacitive ceramic sensor  

*    Height above ground level: 3 metres.

**Relative humidity:** Capacitive thin film polymer sensor  

*    Height above ground level: 3 metres.

**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1  
  
*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Carbon monoxide:** Infrared absorption analyser operated in accordance with AS 3580.7.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**PM10:** Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0).  
*    After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3. 
  </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Rocklea (South East Queensland) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -27.5358; Longitude: 152.9934  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for:  

*    Isolated trees above height of inlet within 10 metres west of the monitoring site.  

**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Isolated trees within 10 metres west of the monitoring site.  
*    Temperature and relative humidity sensors located 10 metres above ground level.  
*    Rainfall measured by acoustic sensor.  

**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*    Height above ground level: 10 metres.  

**Relative humidity:** Capacitive thin film polymer sensor  

*    Height above ground level: 10 metres.  

**Rainfall:** Vaisala RAINCAP® precipitation sensor  

*    Height above ground level: 10 metres.  

**Barometric pressure:** Capacitive silicon sensor  

*    Height above ground level: 10 metres.  

**Solar radiation:** Pyranometer  
**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13  

*    The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*    Reported concentrations are uncorrected instrument output values.  
*    Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1  

*    Detector spectral response centred at 520 nm.  
*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>South Brisbane (South East Queensland) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -27.4848; Longitude: 153.0321  
**AS/NZS 3580.1.1 site classification:** Peak (roadside)  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Wind measurements will be perturbed by elevated ground and roadways to the north and west of the monitoring site.  

**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacative ceramic sensor  
**Relative humidity:** Capacitive thin film polymer sensor  
**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Carbon monoxide:** Infrared absorption analyser operated in accordance with AS 3580.7.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13  

*    The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*    Reported concentrations are uncorrected instrument output values.  
*    Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported. 
  </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>South Gladstone (Gladstone) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -23.8627; Longitude: 151.2704  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Isolated trees within 20 metres of the monitoring site.  
*    Temperature and relative humidity sensors located 10 metres above ground level.  
*    Rainfall measured by acoustic sensor.  

**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*    Height above ground level: 10 metres.  

**Relative humidity:** Capacitive thin film polymer sensor  

*    Height above ground level: 10 metres.  

**Rainfall:** Vaisala RAINCAP® precipitation sensor  

*    Height above ground level: 10 metres.  

**Barometric pressure:** Capacitive silicon sensor  

*    Height above ground level: 10 metres.  

**Solar radiation:** Pyranometer  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13  

*    The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  

*    Reported concentrations are uncorrected instrument output values.  
*    Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1  

*    Detector spectral response centred at 530 nm.  
*    Instrument output offset and/or scaled based on calibration and daily zero/span response data. 
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Springwood (South East Queensland) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -27.6125; Longitude: 153.1356  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for:  

*    Trees above height of PM10/PM2.5 inlets within 5 metres south and west of the monitoring site.  

**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Located below the upper level of a ridge running roughly northwest-southeast.  
*    Trees within 10 metres of the monitoring site (below height of wind sensor).  

**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*    Height above ground level: 3 metres.  

**Ozone, nitrogen dioxide, sulfur dioxide, benzene, toluene, xylenes (total) and formaldehyde:** Differential Optical Absorption Spectroscopy (DOAS) analyser  

*    Values are average concentrations over 250 metre light path running east-west from (-27.6117, 153.1382) to (-27.6125, 153.1359).  
*    Instrument output offset and/or scaled based on instrument calibration data.  

**PM10:** Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0).  
*    After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.  

**PM2.5:** Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8—2001  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Reported values are unadjusted instrument output values as per the requirements of the Air NEPM Technical Paper on Monitoring for Particles as PM2.5.  
*    Negative hourly PM2.5 concentrations down to -5 µg/m^3 are reported. </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Stuart (Townsville) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Industry-operated monitoring site:** Raw data received from industry validated by Queensland Government  
**Period of operation:** 1 January to 31 December 2015 (site offline from 18 May to 3 August due to site infrastructure upgrade)    
**Site location:** Latitude: -19.3212; Longitude: 146.8422  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies fully except for:   

*    Temperature and relative humidity sensors located 10 metres above ground level (4 August to 31 December).
*    Rainfall measured by acoustic sensor (4 August to 31 December).

**Wind sensor:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  

**Temperature:** Capacitive ceramic sensor  

*    Height above ground level: 3 metres (1 January to 17 May) 
*    Height above ground level: 10 metres (4 August to 31 December).

**Relative humidity:**Capacitive thin film polymer sensor  

*    Height above ground level: 3 metres (1 January to 17 May) 
*    Height above ground level: 10 metres (4 August to 31 December).

**Rainfall:** Tipping bucket rain gauge (1 January to 17 May); Vaisala RAINCAP® precipitation sensor (4 August to 31 December)  

*    Height above ground level: 3 metres (1 January to 17 May) 
*    Height above ground level: 10 metres (4 August to 31 December).

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1  
  
*    Instrument output offset and/or scaled based on calibration and daily zero/span response data. </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Targinie (Gladstone) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -23.7743; Longitude: 151.1060  
**AS/NZS 3580.1.1 site classification:** Background  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Trees within 15 metres north west of the monitoring site.  
*    Temperature and relative humidity sensors located 10 metres above ground level.  
*    Rainfall measured by acoustic sensor.  

**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*    Height above ground level: 10 metres.  

**Relative humidity:** Capacitive thin film polymer sensor  

*    Height above ground level: 10 metres.  

**Rainfall:** Vaisala RAINCAP® precipitation sensor  

*    Height above ground level: 10 metres.  

**Barometric pressure:** Capacitive silicon sensor  

*    Height above ground level: 10 metres.  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1
  
*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13  

*    The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*    Reported concentrations are uncorrected instrument output values.  
*    The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.
*    Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1  

*    Detector spectral response centred at 530 nm.  
*    Instrument output offset and/or scaled based on calibration and daily zero/span response data. </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>The Gap (Mount Isa) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -20.7264; Longitude: 139.4977  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Buildings higher than wind sensor located within 20 metres north east and east of the monitoring site.  
*    Monitoring shelter located on concreted surface.  

**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +6 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*    Height above ground level: 3 metres.  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**PM10:** Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0).  
*    After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3. 
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Townsville Coast Guard (Townsville) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Joint Queensland Government / industry-operated monitoring site:** Data validation conducted by the Queensland Government.  
**Period of operation:** 1 January to 31 December 2015  
**Site location: Latitude:** -19.2526; Longitude: 146.8272  
**AS/NZS 3580.1.1 site classification:** Peak (port operations)  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Trees within 5 metres to the west of the industry/joint monitoring station (no obstructions in direction of port operations).  
*    Monitoring stations located on asphalt surface.  

**Wind sensor:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  

**Temperature:** Capacitive ceramic sensor  
**PM10:** Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0).  
*    After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.  

**TSP:** Tapered Element Oscillating Microbalance (TEOM) Model 1405 operated in accordance with AS/NZS 3580.9.13 (excepting FDMS requirements)  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Reported concentrations are uncorrected instrument output values.  
*    Negative hourly TSP concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3. 
  </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>West Mackay (Mackay) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -21.1595; Longitude: 149.1549  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies fully  
**Wind:** Ultrasonic sensor  

*    Height above ground: 10 metres.  
*    The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +9 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**PM10:** Tapered Element Oscillating Balance (TEOM) Model 1405 operated in accordance with AS/NZS 3580.9.13 (excluding FDMS requirements)  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Reported concentrations are uncorrected instrument output values.  
*    Negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1  

*    Detector spectral response centred at 530 nm.  
*    Instrument output offset and/or scaled based on calibration and daily zero/span response data. 
  </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Woolloongabba (South East Queensland) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2015 (no PM10/PM2.5 data after 30 March and temperature/humidity data after 29 July due to instrument faults. Adjacent construction work prevented safe access to the station to replace the faulty equipment.)    
**Site location:** Latitude: -27.4975; Longitude: 153.0350  
**AS/NZS 3580.1.1 site classification:** Peak (roadside)  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    4 storey building located within 10 metres west of the monitoring site (no obstructions in direction of roadway).  

**Wind:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**Relative humidity:** Capacitive thin film polymer sensor  
**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Carbon monoxide:** Infrared absorption analyser operated in accordance with AS 3580.7.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13  

*    The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*    Reported concentrations are uncorrected instrument output values.  
*    The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.
*    Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported. 
  </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Wynnum North (South East Queensland) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Industry-operated monitoring site:** Data presented as received by Queensland Government  
**Period of operation:** 1 January to 31 December 2015  
**Site location:** Latitude: -27.4296; Longitude: 153.1581  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Temperature and relative humidity sensors located 10 metres above ground level.
*    Rainfall measured by acoustic sensor.

**Wind sensor:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  

**Temperature:** Capacitive ceramic sensor  

*    Height above ground level: 10 metres.  

**Relative humidity:** Capacitive thin film polymer sensor  

*    Height above ground level: 10 metres.  

**Rainfall:** Vaisala RAINCAP® precipitation sensor. 

*    Height above ground level: 10 metres.

**Barometric pressure:** Capacitive silicon sensor.  

*    Height above ground level: 10 metres.  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-D operated in accordance with AS/NZS 3580.9.13 (excluding FDMS requirements)  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.  
*    Reported concentrations are uncorrected instrument output values.  
*    Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported. 
  </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Wynnum West (South East Queensland) 2015 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Industry-operated monitoring site:** Data presented as received by Queensland Government  
**Period of operation:** 1 March to December 2015  
**Site location:** Latitude: -27.4379; Longitude: 153.1495  
**AS/NZS 3580.1.1 site classification:** Neighbourhood  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for:  

*    Trees higher than sample inlets within 10m north-west of monitoring station.  
*    Building below height of sample inlets within 10m east of monitoring station.  

**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:  

*    Trees within 10m north-west of monitoring station.  
*    Building below height of wind sensor within 10m east of monitoring station.  
*    Rainfall measured by acoustic sensor.  

**Wind sensor:** Ultrasonic sensor  

*    Height above ground level: 10 metres.  

**Temperature:** Capacitive ceramic sensor  

*    Height above ground level: 10 metres.  

**Relative humidity:** Capacitive thin film polymer sensor  

*    Height above ground level: 10 metres.  

**Rainfall:** Vaisala RAINCAP® precipitation sensor.  

*    Height above ground level: 10 metres.  

**Barometric pressure:** Capacitive silicon sensor.  

*    Height above ground level: 10 metres.  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.  

**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13  

*    The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  

*    Reported concentrations are uncorrected instrument output values.  
*    Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported. 
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
</mdb:MD_Metadata>