<mdb:MD_Metadata xmlns:cit="http://standards.iso.org/iso/19115/-3/cit/2.0" xmlns:gco="http://standards.iso.org/iso/19115/-3/gco/1.0" xmlns:lan="http://standards.iso.org/iso/19115/-3/lan/1.0" xmlns:mcc="http://standards.iso.org/iso/19115/-3/mcc/1.0" xmlns:mdb="http://standards.iso.org/iso/19115/-3/mdb/2.0" xmlns:mrd="http://standards.iso.org/iso/19115/-3/mrd/1.0" xmlns:mri="http://standards.iso.org/iso/19115/-3/mri/1.0" xmlns:xlink="http://www.w3.org/1999/xlink">
    <mdb:metadataIdentifier xlink:type="simple">
        <mcc:MD_Identifier>
            <mcc:code>
                <gco:CharacterString>94ae85af-a62b-4ae4-a86b-631fb9cc4af5</gco:CharacterString>
            </mcc:code>
            <mcc:codeSpace>
                <gco:CharacterString>urn:uuid</gco:CharacterString>
            </mcc:codeSpace>
        </mcc:MD_Identifier>
    </mdb:metadataIdentifier>
    <mdb:defaultLocale xlink:type="simple">
        <lan:PT_Locale>
            <lan:language>
                <lan:LanguageCode codeList="" codeListValue="en">en</lan:LanguageCode>
            </lan:language>
            <lan:characterEncoding>
                <lan:MD_CharacterSetCode codeList="" codeListValue="UTF-8">UTF-8</lan:MD_CharacterSetCode>
            </lan:characterEncoding>
        </lan:PT_Locale>
    </mdb:defaultLocale>
    <mdb:metadataScope xlink:type="simple">
        <mdb:MD_MetadataScope>
            <mdb:resourceScope>
                <mcc:MD_ScopeCode codeList="" codeListValue="nonGeographicDataset">nonGeographicDataset</mcc:MD_ScopeCode>
            </mdb:resourceScope>
            <mdb:name>
                <gco:CharacterString>nonGeographicDataset</gco:CharacterString>
            </mdb:name>
        </mdb:MD_MetadataScope>
    </mdb:metadataScope>
    <mdb:contact xlink:type="simple" />
    <mdb:dateInfo xlink:type="simple">
        <cit:CI_Date>
            <cit:date>
                <gco:DateTime>2025-11-11T11:53:26</gco:DateTime>
            </cit:date>
            <cit:dateType>
                <cit:CI_DateTypeCode codeList="" codeListValue="creation">creation</cit:CI_DateTypeCode>
            </cit:dateType>
        </cit:CI_Date>
    </mdb:dateInfo>
    <mdb:metadataStandard xlink:type="simple">
        <cit:CI_Citation>
            <cit:title>
                <gco:CharacterString>ISO 19115</gco:CharacterString>
            </cit:title>
            <cit:edition>
                <gco:CharacterString>2016</gco:CharacterString>
            </cit:edition>
        </cit:CI_Citation>
    </mdb:metadataStandard>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Air Quality Monitoring - 2011</gco:CharacterString>
                    </cit:title>
                    <cit:identifier xlink:type="simple">
                        <mcc:MD_Identifier>
                            <mcc:code>
                                <gco:CharacterString>94ae85af-a62b-4ae4-a86b-631fb9cc4af5</gco:CharacterString>
                            </mcc:code>
                        </mcc:MD_Identifier>
                    </cit:identifier>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>Annual hourly air quality and meteorological data by monitoring site for the 2011 calendar year.
For more information on Air Quality including live air data, please visit environment.des.qld.gov.au/air.
Data resolution: One hour average values
Data row timestamp: Start of averaging period
Missing data/not monitored: Blank cell
Calm conditions: No hourly average wind direction is reported when the hourly average wind speed is zero
Daily zero/span response check: Automated instrument zero/span response checks are conducted daily between midnight and 1:00am.  Where this takes place, an ambient hourly value cannot be reported.
Sampling height: 4 metres above ground level (unless otherwise indicated)
Please note: The following datasets were added on 03 May 2018:

Pinkenba
Pomona
Stuart
Townsville Port
Wynnum North

Please note: The following datasets were updated on 03 May 2018

Pimlico - Oxides of nitrogen modified
South Brisbane - Carbon monoxide modified
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:descriptiveKeywords xlink:type="simple">
                <mri:MD_Keywords>
                    <mri:keyword>
                        <gco:CharacterString>The Science Sandpit</gco:CharacterString>
                    </mri:keyword>
                </mri:MD_Keywords>
            </mri:descriptiveKeywords>
            <mri:descriptiveKeywords xlink:type="simple">
                <mri:MD_Keywords>
                    <mri:keyword>
                        <gco:CharacterString>air</gco:CharacterString>
                    </mri:keyword>
                </mri:MD_Keywords>
            </mri:descriptiveKeywords>
            <mri:descriptiveKeywords xlink:type="simple">
                <mri:MD_Keywords>
                    <mri:keyword>
                        <gco:CharacterString>air quality</gco:CharacterString>
                    </mri:keyword>
                </mri:MD_Keywords>
            </mri:descriptiveKeywords>
            <mri:descriptiveKeywords xlink:type="simple">
                <mri:MD_Keywords>
                    <mri:keyword>
                        <gco:CharacterString>environment</gco:CharacterString>
                    </mri:keyword>
                </mri:MD_Keywords>
            </mri:descriptiveKeywords>
            <mri:descriptiveKeywords xlink:type="simple">
                <mri:MD_Keywords>
                    <mri:keyword>
                        <gco:CharacterString>science</gco:CharacterString>
                    </mri:keyword>
                </mri:MD_Keywords>
            </mri:descriptiveKeywords>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Aldoga (Gladstone) 2011 hourly meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -23.8403;  Longitude: 151.0628  
**AS/NZS 3580.1.1:2007 site classification:** Background  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies fully  
**Wind sensor:** Mechanical cup and vane.  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.  

**Temperature:** Platinum resistance sensor  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Arundel (Gold Coast) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -27.9441;  Longitude: 153.3656  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies with the exception of the following:  

*   Three-story building within 20 metres SW of the monitoring site  
*   Trees above height of inlet within 20 metres W of the monitoring site  

**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Located on northern side of slope below a ridge running east-west  
*   Three-story building within 20 metres SW of the monitoring site  
*   Trees within 20 metres W of the monitoring site  
*   Temperature and relative humidity sensors located at a height of 10 metres above ground level  
*   Monitoring shelter located on paved area  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*   Height above ground level: 10 metres  

**Relative humidity:** Capacitive thin film polymer sensor  

*   Height above ground level: 10 metres  

**Rainfall:** Vaisala RAINCAP® precipitation sensor  

*   Height above ground level: 10 metres  

**Barometric pressure:** Capacitive silicon sensor  

*   Height above ground level: 10 metres  

**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1—2011  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2011  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**PM10 / PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13—2013  

*   The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*   Reported concentrations are uncorrected instrument output values.  
*   Negative hourly PM10 / PM2.5 concentrations down to -5 µg/m3 resulting from instrument noise at low particle concentrations are reported.  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Auckland Point (Gladstone) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  

*   Monitoring of temperature and PM10 commenced on 7 June 2011  

**Site location:** Latitude: -23.8351;  Longitude: 151.2539  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies with the exception of the following:  

*   DOAS light path between 4 metres and 25 metres above ground level  

**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Located on southern side of slope below a ridge  
*   Trees within 20 metres of the monitoring site  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**Ozone, nitrogen dioxide, sulfur dioxide, benzene, toluene, xylenes (total), formaldehyde:** Differential Optical Absorption Spectroscopy (DOAS) analyser  

*   Value is average concentration over 680 metre light path running north-south from ‑23.8351, 151.2539 to -23.8409,151.2550  
*   Instrument output offset and/or scaled based on instrument calibration data  

**PM10:** Tapered Element Oscillating Balance (TEOM) operated in accordance with AS 3580.9.8—2001  

*   Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter  
*   Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0)  
*   After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m3 are removed and concentrations between -0.5 µg/m3 and 0.0 µg/m3 are set to 0.0 µg/m3  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Ayr (Ayr) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 2 March (site established) to 31 December 2011  
**Site location:** Latitude: -19.5839;  Longitude: 147.4059  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood   
**AS/NZS 3580.1.1:2007 compliance:** Complies fully  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Trees within 15 metres of the monitoring site  
*   Monitoring shelter located on concreted surface  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +8 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**PM10:** Tapered Element Oscillating Balance (TEOM) operated in accordance with AS 3580.9.8—2001  

*   Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter  
*   Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0)  
*   After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m3 are removed and concentrations between -0.5 µg/m3 and 0.0 µg/m3 are set to 0.0 µg/m3  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1:2001  

*   Detector spectral response centred at 530 nm.  
*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Boat Creek (Gladstone) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  

*   Site was offline from 20 April to 24 July 2011 due to loss of power supply during construction works taking place on the property where the monitoring station is located  

**Site location:** Latitude: -23.8199;  Longitude: 151.1538  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies fully  
**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**Relative humidity:** Capacitive thin film polymer sensor  
**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1—2008  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**PM10 / PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13—2013  

*   The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*   Reported concentrations are uncorrected instrument output values.  
*   Negative hourly PM10 / PM2.5 concentrations down to -5 µg/m3 resulting from instrument noise at low particle concentrations are reported.  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1:2001  

*   Detector spectral response centred at 530 nm.  
*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Boyne Island (Gladstone) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -23.9408;  Longitude: 151.3507  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Located on eastern side of slope below a ridge running north-south  
*   Trees within 20 metres of the monitoring site  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**Relative humidity:** Capacitive thin film polymer sensor  
**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1—2008  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Carbon monoxide:** Infrared absorption analyser operated in accordance with AS 3580.7.1—2011  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**PM10 / PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13—2013  

*   The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*   Reported concentrations are uncorrected instrument output values.  
*   Negative hourly PM10 / PM2.5 concentrations down to -5 µg/m3 resulting from instrument noise at low particle concentrations are reported.  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1:2001  

*   Detector spectral response centred at 530 nm.  
*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Brisbane CBD (Brisbane) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  

*   Wind sensor failed 12 January 2011.  Due to building refurbishment works it was not possible to access the roof to replace the faulty sensor until 9 September 2011.  
*   Temperature monitoring commenced on 3 February 2011  

**Region:** South East Queensland  
**Site location:** Latitude: -27.4774;  Longitude: 153.0281  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies with the exception of the following:  

*   Equipment located in room on sixth floor of building  
*   Nephelometer inlet located on eastern side of building, 1 metre out from building  
*   PM10 inlet located on building roof above equipment room, 1 metre above roof surface  
*   Building lift shaft higher than PM10 inlet located 8 metres S of inlet  

**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Building lift shaft higher than wind sensor and within 10 metres of sensor  
*   Buildings higher than wind sensor located within 40 metres of sensor  
*   Temperature sensor located in non-aspirated radiation shield 1 metre above roof surface  

**Wind:** Ultrasonic sensor  

*   Height above roof level: 4 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**PM10:** Tapered Element Oscillating Balance (TEOM) operated in accordance with AS 3580.9.8—2001  

*   Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter  
*   Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0)  
*   After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m3 are removed and concentrations between -0.5 µg/m3 and 0.0 µg/m3 are set to 0.0 µg/m3  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1:2001  

*   Detector spectral response centred at 530 nm.  
*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Clinton (Gladstone) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -23.8701;  Longitude: 151.2216  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Temperature and relative humidity sensors located at a height of 10 metres above ground level  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*   Height above ground level: 10 metres  

**Relative humidity:** Capacitive thin film polymer sensor  

*   Height above ground level: 10 metres  

**Rainfall:** Vaisala RAINCAP® precipitation sensor  

*   Height above ground level: 10 metres  

**Barometric pressure:** Capacitive silicon sensor  

*   Height above ground level: 10 metres  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1—2008  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**PM10 / PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13—2013  

*   The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*   Reported concentrations are uncorrected instrument output values.  
*   Negative hourly PM10 / PM2.5 concentrations down to -5 µg/m3 resulting from instrument noise at low particle concentrations are reported.  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1:2001  

*   Detector spectral response centred at 530 nm.  
*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Deception Bay (South East Queensland) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -27.1935;  Longitude: 153.0347  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Trees within 15 metres of the monitoring site  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Flinders View (Ipswich) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -27.6528;  Longitude: 152.7741  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies with the exception of the following:  

*   Trees above height of inlet within 10 metres of the monitoring site  

**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Located on western side of slope below a ridge running northeast-southwest  
*   Trees within 10 metres of the monitoring site (below height of wind sensor)  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**Relative humidity:** Capacitive thin film polymer sensor  
**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1—2008  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**PM10:** Tapered Element Oscillating Balance (TEOM) operated in accordance with AS 3580.9.8—2001  

*   Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter  
*   Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0)  
*   After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m3 are removed and concentrations between -0.5 µg/m3 and 0.0 µg/m3 are set to 0.0 µg/m3  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1:2001  

*   Detector spectral response centred at 530 nm.  
*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Gatton (South East Queensland) 2011 hourly meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -27.5434;  Longitude: 152.3343  
**AS/NZS 3580.1.1:2007 site classification:** Background  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies fully  
**Wind sensor:** Mechanical cup and vane.  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Platinum resistance sensor  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Josephville (South East Queensland) 2011 hourly meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -28.0121;  Longitude: 152.9217  
**AS/NZS 3580.1.1:2007 site classification:** Background  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Temperature and relative humidity sensors located at a height of 10 metres above ground level  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*   Height above ground level: 10 metres  

**Relative humidity:** Capacitive thin film polymer sensor  

*   Height above ground level: 10 metres  

**Rainfall:** Vaisala RAINCAP® precipitation sensor  

*   Height above ground level: 10 metres  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Lutwyche (Brisbane) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 27 April (site established) to 31 December 2011  
**Site location:** Latitude: -27.4166;  Longitude: 153.0376  
**AS/NZS 3580.1.1:2007:** Peak (roadway construction works)  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies with the exception of the following:  

*   Building higher than inlet within 20 metres S of monitoring site  

**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Building higher than wind sensor located within 20 metres S of monitoring site  
*   Monitoring shelter located on asphalted surface  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 6 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*   Height above ground level: 10 metres  

**Relative humidity:** Capacitive thin film polymer sensor  

*   Height above ground level: 10 metres  

**PM10 / PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13—2013  

*   The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*   Reported concentrations are uncorrected instrument output values.  
*   Negative hourly PM10 / PM2.5 concentrations down to -5 µg/m3 resulting from instrument noise at low particle concentrations are reported.  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Memorial Park (Gladstone) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -23.8443;  Longitude: 151.2517  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies with the exception of the following:  

*   DOAS light path between 4 metres and 25 metres above ground level  

**Ozone, nitrogen dioxide, sulfur dioxide, benzene, toluene, xylenes (total), formaldehyde:** Differential Optical Absorption Spectroscopy (DOAS) analyser  

*   Reported value is average concentration over 500 metre light path running southwest-northeast from ‑23.8443, 151.2517 to -23.8409,151.2550  
*   Instrument output offset and/or scaled based on instrument calibration data  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Menzies (Mount Isa) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -20.7167;  Longitude: 139.4920  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies with the exception of the following:  

*   Trees above height of inlet within 10 metres of the monitoring site  

**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Trees within 10 metres of the monitoring site  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +6 degrees to the sensor output value.  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1—2008  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Moranbah (Moranbah) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 10 March (site established) to 31 December 2011  
**Site location:** Latitude: -21.9995;  Longitude: 148.0713  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies fully  
**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +8 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*   Sensor mounted in non-aspirated radiation shield – under still conditions reported temperature can be higher than actual  

**PM10:** Tapered Element Oscillating Balance (TEOM) operated in accordance with AS 3580.9.8—2001  

*   Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter  
*   Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0)  
*   After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m3 are removed and concentrations between -0.5 µg/m3 and 0.0 µg/m3 are set to 0.0 µg/m3  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Mountain Creek (Sunshine Coast) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -26.6917;  Longitude: 153.1038  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies fully  
**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**PM10:** Tapered Element Oscillating Balance (TEOM) operated in accordance with AS 3580.9.8—2001  

*   Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter  
*   Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0)  
*   After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m3 are removed and concentrations between -0.5 µg/m3 and 0.0 µg/m3 are set to 0.0 µg/m3  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1:2001  

*   Detector spectral response centred at 530 nm.  
*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Mutdapilly (South East Queensland) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -27.7528;  Longitude: 152.6509  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies fully  
**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>North Maclean (South East Queensland) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -27.7708;  Longitude: 153.0300  
**AS/NZS 3580.1.1:2007 site classification:** Background  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Temperature and relative humidity sensors located at a height of 10 metres above ground level  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*   Height above ground level: 10 metres (from 1 December)  

**Relative humidity:** Capacitive thin film polymer sensor  

*   Height above ground level: 10 metres (from 1 December)  

**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Pimlico (Townsville) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -19.2871;  Longitude: 146.7813  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Isolated trees within 20 metres of the monitoring site  
*   Three storey building located within 30 metres to the south of the monitoring site  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +8 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*   Sensor mounted in non-aspirated radiation shield – under still conditions reported temperature can be higher than actual  

**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1—2008  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**PM10:** Tapered Element Oscillating Balance (TEOM) operated in accordance with AS 3580.9.8—2001  

*   Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter  
*   Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0)  
*   After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m3 are removed and concentrations between -0.5 µg/m3 and 0.0 µg/m3 are set to 0.0 µg/m3  

**Please note:** This dataset was updated to modify oxides of nitrogen values on 03 May 2018</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Pinkenba (South East Queensland) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Industry-operated monitoring site:** Data presented as received by Queensland Government  
**Period of operation:** 3 February to 31 December 2011 (site offline 1 January to 2 February while repairs to monitoring station carried out)  
**Site location:** Latitude: -27.4205; Longitude: 153.1208  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14:2011 compliance (meteorology):** Complies fully  
**Wind sensor:** Ultrasonic sensor  

*    Height above ground level: 10 metres. 

**Temperature:** Capacitive ceramic sensor

*    Height above ground level: 3 metres. 

**Relative humidity:** Capacitive thin film polymer sensor

*    Height above ground level: 3 metres. 

**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.

**Carbon monoxide:** Infrared absorption analyser operated in accordance with AS 3580.7.1

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.

**PM10:** Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8  

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.
*    Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0). 
*    After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Pomona (Sunshine Coast, South East Queensland) 2011 hourly meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 16 September 2011 (site closed)  
**Site location:** Latitude: -26.3124; Longitude: 152.9536  
**AS/NZS 3580.1.1:2007 site classification:** Background  
**AS/NZS 3580.14:2011 compliance (meteorology):** Complies, except for:  

*    Temperature and relative humidity sensors located 10 metres above ground level.

**Wind sensor:** Ultrasonic sensor

*    Height above ground level: 10 metres. 
*    The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.

**Temperature:** Capacitive ceramic sensor

*    Height above ground level: 10 metres. 

**Relative humidity:** Capacitive thin film polymer sensor

*    Height above ground level: 10 metres. 

**Rainfall:** Vaisala RAINCAP® precipitation sensor. 

*    Height above ground level: 10 metres.</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Rocklea (Brisbane) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 11 January 2011 (site offline due to flood damage)  

*   Monitoring site damaged by severe flooding and offline for remainder of year awaiting replacement monitoring station infrastructure  

**Site location:** Latitude: -27.5358;  Longitude: 152.9934  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies with the exception of the following:  

*   Isolated trees above height of inlet within 10 metres to the west of the monitoring site  

**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Temperature and relative humidity sensors located at a height of 10 metres above ground level  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Platinum resistance sensor  
**Relative humidity:** Capacitive thin film polymer sensor  
**Rainfall:** Tipping bucket gauge  
**Solar radiation:** Pyranometer  
**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**PM10 / PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13—2013  

*   The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*   Reported concentrations are uncorrected instrument output values.  
*   Negative hourly PM10 / PM2.5 concentrations down to -5 µg/m3 resulting from instrument noise at low particle concentrations are reported.  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1:2001  

*   Detector spectral response centred at 525 nm.  
*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>South Brisbane (Brisbane) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -27.4848;  Longitude: 153.0321  
**AS/NZS 3580.1.1:2007 site classification:** Peak (roadside)  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Wind measurements will be perturbed by elevated ground and roadways to the north and west of the monitoring site  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**Relative humidity:** Capacitive thin film polymer sensor  
**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Carbon monoxide:** Infrared absorption analyser operated in accordance with AS 3580.7.1—2011  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**PM10 / PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13—2013  

*   The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*   Reported concentrations are uncorrected instrument output values.  
*   Negative hourly PM10 / PM2.5 concentrations down to -5 µg/m3 resulting from instrument noise at low particle concentrations are reported.  

**Please note:** This dataset was updated to modify carbon monoxide values on 03 May 2018</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>South Gladstone (Gladstone) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -23.8626;  Longitude: 151.2705  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Isolated trees within 20 metres of the monitoring site  
*   Temperature and relative humidity sensors located at a height of 10 metres above ground level  
*   Monitoring shelter located on concrete surface  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*   Height above ground level: 10 metres  

**Relative humidity:** Capacitive thin film polymer sensor  

*   Height above ground level: 10 metres  

**Rainfall:** Vaisala RAINCAP® precipitation sensor  

*   Height above ground level: 10 metres  

**Solar radiation:** Pyranometer  
**Barometric pressure:** Capacitive silicon sensor  

*   Height above ground level: 10 metres  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1—2008  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**PM10 / PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13—2013  

*   The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*   Reported concentrations are uncorrected instrument output values.  
*   Negative hourly PM10 / PM2.5 concentrations down to -5 µg/m3 resulting from instrument noise at low particle concentrations are reported.  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1:2001  

*   Detector spectral response centred at 530 nm.  
*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Springwood (South East Queensland) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -27.6125;  Longitude: 153.1359  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies with the exception of the following:  

*   Trees above height of PM10/PM2.5 inlets within 5 metres to the south and west of the monitoring site  

**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Located below the level of a ridge running roughly northwest-southeast  
*   Trees within 10 metres of the monitoring site (below height of wind sensor)  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**Ozone, nitrogen dioxide, sulfur dioxide, benzene, toluene, xylenes (total), formaldehyde:** Differential Optical Absorption Spectroscopy (DOAS) analyser  

*   Value is average concentration over 250 metre light path running east-west from ‑27.6117, 153.1382 to -27.6125,153.1359  
*   Instrument output offset and/or scaled based on instrument calibration data  

**PM10:** Tapered Element Oscillating Balance (TEOM) operated in accordance with AS 3580.9.8—2001  

*   Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter  
*   Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0)  
*   After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m3 are removed and concentrations between -0.5 µg/m3 and 0.0 µg/m3 are set to 0.0 µg/m3  

**PM2.5:** Tapered Element Oscillating Balance (TEOM) operated in accordance with AS 3580.9.8—2001  

*   Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter  
*   Reported values are unadjusted instrument output values as per the requirements of the Air NEPM Technical Paper on Monitoring for Particles as PM2.5  
*   Negative hourly PM2.5 concentrations down to -5 µg/m3 are reported.  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Stuart (Townsville) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Industry-operated monitoring site:** Raw data received from industry validated by Queensland Government  
**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -19.3212; Longitude: 146.8422  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14:2011 compliance (meteorology):** Complies fully  
**Wind sensor:** Ultrasonic sensor  

*    Height above ground level: 10 metres. 

**Temperature:** Capacitive ceramic sensor  
**Relative humidity:** Capacitive thin film polymer sensor  
**Rainfall:** Tipping bucket rain gauge.   
**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1—2008.

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Targinie (Gladstone) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -23.7744;  Longitude: 151.1055  
**AS/NZS 3580.1.1:2007 site classification:** Background  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Trees within 15 metres NW of the monitoring site  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  

*   Height above ground level: 10 metres  

**Relative humidity:** Capacitive thin film polymer sensor  

*   Height above ground level: 10 metres  

**Rainfall:** Vaisala RAINCAP® precipitation sensor  

*   Height above ground level: 10 metres  

**Barometric pressure:** Capacitive silicon sensor  

*   Height above ground level: 10 metres  

**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1—2008  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**PM10 / PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13—2013  

*   The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*   Reported concentrations are uncorrected instrument output values.  
*   Negative hourly PM10 / PM2.5 concentrations down to -5 µg/m3 resulting from instrument noise at low particle concentrations are reported.  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1:2001  

*   Detector spectral response centred at 530 nm.  
*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>The Gap (Mount Isa) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -20.7264;  Longitude: 139.4977  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Buildings higher than wind sensor located within 20 metres northeast and east of the monitoring site  
*   Monitoring shelter located on concreted surface  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +6 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1—2008  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**PM10:** Tapered Element Oscillating Balance (TEOM) operated in accordance with AS 3580.9.8—2001  

*   Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter  
*   Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0)  
*   After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m3 are removed and concentrations between -0.5 µg/m3 and 0.0 µg/m3 are set to 0.0 µg/m3  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Townsville Coast Guard (Townsville) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  

*   Site offline from 1 February to 26 July due to cyclone damage to monitoring shelter  

**Site location:** Latitude: -19.2542;  Longitude: 146.8257  
**AS/NZS 3580.1.1:2007 site classification:** Peak (Port operations)  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Monitoring shelter located on concreted surface  

**Temperature:** Capacitive ceramic sensor  
**TSP:** Tapered Element Oscillating Balance (TEOM) operated in accordance with AS 3580.9.8—2001  

*   Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter  
*   Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements for PM10 (scaled by 1.03, offset by +3.0)  
*   After adjustment, negative hourly TSP concentrations less than -0.5 µg/m3 are removed and concentrations between -0.5 µg/m3 and 0.0 µg/m3 are set to 0.0 µg/m3  </gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Townsville Port (Townsville) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Industry-operated monitoring site:** Data received from industry validated by Queensland Government  
**Period of operation:** 1 January to 31 August 2011 (site closed)  
**Site location:** Latitude: -19.2502; Longitude: 146.8304  
**AS/NZS 3580.1.1 site classification:** Peak (port operations)  
**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully   
**AS/NZS 3580.14 compliance (meteorology):** Complies fully  
**Wind:** Mechanical propellor and vane sensor  

*    Height above ground level: 10 metres. 

**PM10 (to 1 February):** Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter. 
*    Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0). 
*    After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>West Mackay (Mackay) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -21.1595;  Longitude: 149.1549  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies fully  
**Wind:** Ultrasonic sensor  

*   Height above roof level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +9 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**PM10:** Tapered Element Oscillating Balance (TEOM) operated in accordance with AS 3580.9.8—2001  

*   Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter  
*   Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0)  
*   After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m3 are removed and concentrations between -0.5 µg/m3 and 0.0 µg/m3 are set to 0.0 µg/m3  

**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1:2001  

*   Detector spectral response centred at 530 nm.  
*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Woolloongabba (Brisbane) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -27.4975;  Longitude: 153.0350  
**AS/NZS 3580.1.1:2007 site classification:** Peak (roadside)  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14—2011 compliance (meteorology):** Complies with the exception of the following:  

*   Four storey building located within 10 metres west of monitoring site  

**Wind:** Ultrasonic sensor  

*   Height above ground level: 10 metres  
*   The wind direction sensor is aligned to magnetic north.  The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.  

**Temperature:** Capacitive ceramic sensor  
**Relative humidity:** Capacitive thin film polymer sensor  
**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2010  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**Carbon monoxide:** Infrared absorption analyser operated in accordance with AS 3580.7.1—2011  

*   Instrument output offset and/or scaled based on calibration and daily zero/span response data  

**PM10 / PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13—2013  

*   The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.  
*   Reported concentrations are uncorrected instrument output values.  
*   Negative hourly PM10 / PM2.5 concentrations down to -5 µg/m3 resulting from instrument noise at low particle concentrations are reported.  
</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
    <mdb:identificationInfo xlink:type="simple">
        <mri:MD_DataIdentification>
            <mri:citation xlink:type="simple">
                <cit:CI_Citation>
                    <cit:title>
                        <gco:CharacterString>Wynnum North (South East Queensland) 2011 hourly air quality and meteorological data</gco:CharacterString>
                    </cit:title>
                    <cit:presentationForm>
                        <cit:CI_PresentationFormCode codeList="" codeListValue="documentDigital">documentDigital</cit:CI_PresentationFormCode>
                    </cit:presentationForm>
                </cit:CI_Citation>
            </mri:citation>
            <mri:abstract>
                <gco:CharacterString>**Industry-operated monitoring site:** Data presented as received by Queensland Government  
**Period of operation:** 1 January to 31 December 2011  
**Site location:** Latitude: -27.4296; Longitude: 153.1581  
**AS/NZS 3580.1.1:2007 site classification:** Neighbourhood  
**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully  
**AS/NZS 3580.14:2011 compliance (meteorology):** Complies fully  
**Wind sensor:** Ultrasonic sensor  

*    Height above ground level: 10 metres. 

**Temperature:** Capacitive ceramic sensor  
**Relative humidity:** Capacitive thin film polymer sensor  
**Rainfall:** Tipping bucket rain gauge.   
**Barometric pressure:** Capacitive silicon sensor.  
**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1  

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.

**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1

*    Instrument output offset and/or scaled based on calibration and daily zero/span response data.

**PM10:** Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter. 
*    Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0). 
*    After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.

**PM2.5:** Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8

*    Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter. 
*    Reported values are unadjusted instrument output values as per the requirements of the Air NEPM Technical Paper on Monitoring for Particles as PM2.5. 
*    Negative hourly PM2.5 concentrations less than -0.5 µg/m^3  are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.</gco:CharacterString>
            </mri:abstract>
            <mri:additionalDocumentation xlink:type="simple" />
            <mri:resourceFormat xlink:type="simple">
                <mrd:MD_Format>
                    <mrd:formatSpecificationCitation xlink:type="simple">
                        <cit:CI_Citation>
                            <cit:title>
                                <gco:CharacterString>CSV</gco:CharacterString>
                            </cit:title>
                        </cit:CI_Citation>
                    </mrd:formatSpecificationCitation>
                </mrd:MD_Format>
            </mri:resourceFormat>
        </mri:MD_DataIdentification>
    </mdb:identificationInfo>
</mdb:MD_Metadata>